Datecs DPP-450 Manual do Utilizador Página 32

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 38
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 31
DATECS DPP-450 Programmer’s Manual
direction doesn’t matter).
If some part of the rectangle is outside the page, only the part inside the
page is filled. The box thickness is always to the inner side of the rectangle.
The command is invalid in standard mode.
The command is supported in firmware version 1.42 or higher.
95. Printing the non blank page area only in page mode (GS Z)
Code: [1Dh] + [5Ah]
The command checks the whole memory of the page mode. The area from the first horizontal line
wit at least 1 black dot to the last such line is printed. The printer does not leave page mode, current
page start position and sizes are not changed. The printed width is 832 dots.
The command is invalid in standard mode.
The command is supported in firmware version 1.42 or higher.
96. Specifying the relative vertical position in page mode (GS \)
Code: [1Dh] + [5Ch] + nL + nH
nL Lower byte of the new vertical
position nH Higher byte of the
new vertical position
The command sets new vertical print position relative to the current one. If the position is outside
the currently active page, the command is not accepted. The real new coordinates depend on the
print direction (selected using GS T). The command is invalid in standard mode.
The horizontal position is changed with commands ESC $ and ESC \ - they work both in page and
standard mode.
The relative vertical offset is nL + 256*nH dots. Offsets in negative direction are given as complement
of 65536 (n
-
=65536 - n).
The command is supported in firmware version 1.42 or higher.
97. Executing macro (GS ^)
Code: [1Dh] + [5Еh] + n1 + n2 + n3
n1 is between 1 and 255: The number of times of macro execution.
n2 is between 1 and 255: Waiting time on macro execution. Waiting time of n2 x 100 msec is
given for every execution.
n3 Macro execution mode. Possible values are:
0 Continuous execution: The Macro is executed n1 times continuously at the
time intervals specified by n2.
1 Execution by LF switch: When LF switch is pressed, the macro is executed once.1
99. Setting the Real Time Clock (GS c)
Code: [1Dh] + [63h] + YY MM DD WW hh mm[00h]
where:
YY Year without the century (00-99)
MM Month (01-12)
DD Day (01-31)
WW Day of the week (01-07)
Vista de página 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 38

Comentários a estes Manuais

Sem comentários